Getting started. From a PLC to a screen.

Scadex is SCADA software that runs on your own machine. Connect a PLC over OPC UA or Modbus TCP, read what it says and put it on a screen your operators can use.

  • One container to install
  • Works fully offline
  • Your data stays in your network
  • A documented API

From a PLC to a screen

From a PLC to a screen in five steps.

Once Scadex is running, this is the whole path: connect a PLC, read it, make tags, set alarms and history, and put it on a screen.

Step 1 of 5: Connect a PLC
  1. Step 1 of 5

    Connect a PLC

    Add the address of a PLC and Scadex connects over OPC UA, keeps trying if it drops, and shows you whether it is connected.

    Quickstart

    1. Add the PLC's address
    2. It connects and keeps trying
    3. Test the connection
    The Scadex OPC UA page: a server named Plant PLC at an opc.tcp address, connected, with no tags yet and a button to browse its address space.The Scadex OPC UA page: a server named Plant PLC at an opc.tcp address, connected, with no tags yet and a button to browse its address space.

    Shown with a virtual PLC. OPC UA has also read a Siemens S7-1500.

  2. Step 2 of 5

    Read it

    Browse the PLC's address space and look at any value, live, before you decide to keep it.

    1. Open the PLC's folders
    2. See each value, live
    3. Pick what you need
    The same connection on its Browse tab: the PLC's folders opened down to six variables of a tank, each with its live value and its address.The same connection on its Browse tab: the PLC's folders opened down to six variables of a tank, each with its live value and its address.
  3. Step 3 of 5

    Create tags

    Tick the values you want. Each becomes a tag: a named value with its live reading and its quality, under a folder you choose.

    How tags work

    1. Tick the values you want
    2. Choose where they go
    3. Create the tags
    The Browse tab with four of the six values ticked, and a bar at the foot: 4 selected, under Plant_PLC, Clear and Create 4 tags.The Browse tab with four of the six values ticked, and a bar at the foot: 4 selected, under Plant_PLC, Clear and Create 4 tags.
  4. Step 4 of 5

    Set alarms and history

    Give a tag a limit and a severity, and keep its history. Operators see what needs attention first, and acknowledge it.

    How alarms work

    1. Set a limit
    2. Choose its severity
    3. Add the alarm
    The tag editor of a tank level tag on its Alarms section, with Scaling and Historian beside it: a new alarm named Level high, greater than 85, severity High, with the current value shown under the setpoint, and an Add alarm button.The tag editor of a tank level tag on its Alarms section, with Scaling and Historian beside it: a new alarm named Level high, greater than 85, severity High, with the current value shown under the setpoint, and an Add alarm button.
  5. Step 5 of 5

    Build a screen

    Draw an operator screen in the browser, or start from the example plant, and open it for operators. Charts and tables come from the same tags.

    About screens

    1. Draw a screen in the browser
    2. Or start from the example plant
    3. Open it for operators
    The Scadex dashboard showing the example water-treatment plant: a process diagram with tanks, pumps and valves, a trend and live values.The Scadex dashboard showing the example water-treatment plant: a process diagram with tanks, pumps and valves, a trend and live values.
  6. Finished

    Your plant, on a screen.

    A PLC connected, its values kept as tags with alarms and history, and a screen your operators open in a browser. Shown: the example plant.

    • Connect a PLC
    • Read it
    • Create tags
    • Set alarms and history
    • Build a screen
    The finished result: the example plant's process diagram with tanks, pumps and valves, a trend and live values, open in the browser.The finished result: the example plant's process diagram with tanks, pumps and valves, a trend and live values, open in the browser.

Not installed yet?

One container, one command and a browser.

No client installs, no licence server and no cloud account, and a plant engineer can do it alone.

Env file · .env
  1. SCADEX_TAG=0.1.0

    The version of Scadex to start.

  2. SCADEX_UID=1000

    The user id the container runs as.

  3. SCADEX_GID=1000

    The group id the container runs as.

Shell
  1. docker login registry.gitlab.com

    Signs in to the place the Scadex image is kept. The login comes with your order.

  2. mkdir modules

    Makes a folder named modules.

  3. docker compose up -d

    Starts Scadex in the background.

  4. # The dashboard is then at http://<this machine>:8080.
  5. # The first account needs the setup token from the log:
  6. docker compose logs gateway | grep -B1 -A3 "setup token"

    Shows the setup token you enter on the first screen.

Browse to port 8080 on that machine and enter the setup token from the gateway's log. The first account is the administrator.

Interested in learning more?

Tell us about your plant and what you run today, or what you want to build on it. We answer in plain language.