Skip to content

Guide

What is SCADA?

SCADA stands for supervisory control and data acquisition. It is the software that lets people see and steer industrial equipment from one place.

In plain words

Equipment on one side, people on the other.

A plant has equipment that measures and moves things: sensors, pumps, valves, drives and the controllers that run them. A SCADA system sits above them. It reads their values, shows them on screens, raises an alarm when something leaves its limits, records what happened, and lets an operator with the right role send a setpoint or a command back.

The name has two halves. Data acquisition is the reading: collecting values from many controllers and keeping them. Supervisory control is the steering: a person, or a script, asks the controllers to do something, while the controllers keep running their own control programs.

The parts

What a SCADA system is made of.

Field devices

Sensors, switches, drives and valves measure and move things in the plant.

Controllers

PLCs and RTUs read the field devices and run the control program, whether or not SCADA is watching.

Communication

A protocol such as OPC UA, Modbus TCP or MQTT carries values between the controllers and the SCADA server.

The SCADA server

One list of values with their quality and time, the alarms, and the record of what happened.

Operator screens

Screens in a browser show the plant, take setpoints and list the alarms, for each person's role.

People and security

Every user has a role, and every change is recorded with who made it and when.

In Scadex these are the drivers, the core, the historian, the views and the roles. See the architecture

What it does

What you use it for.

Monitor

See live values with their quality and time, so you know what is current and what is stale.

Raise alarms

Be told when a value leaves its limits, acknowledge it, and look back at everything that happened.

Send setpoints

Write a setpoint or a command to a controller, with a record of who sent it.

Keep history

Record values and events for trends, reports and reviewing an incident. Scadex can replay any moment.

Share the data

Give other systems and your own tools the same data, through open interfaces.

Protocols

How SCADA talks to equipment.

OPC UA

A standard for exchanging industrial data. A server offers a browsable address space of objects and variables, and clients subscribe to the ones they need.

OPC UA in Scadex

Modbus TCP

A simple protocol that reads and writes numbered registers and coils over a network. Many PLCs, meters and drives speak it.

Modbus TCP in Scadex

MQTT

A light publish-and-subscribe protocol. Devices publish values to topics on a broker, and clients subscribe to the topics they care about.

MQTT in Scadex

Many other protocols exist for particular industries. Scadex connects to these three, and takes in Telegraf agents.

Not the same thing

SCADA, PLC and HMI.

How a PLC, an HMI and SCADA differ
NameWhat it doesWhere it runs
PLCRuns the control program of a machine or a process, and keeps running it without SCADA.Next to the equipment
HMIAn operator screen, often for one machine.At the machine, or in a browser
SCADASupervises many controllers: values, alarms, history, screens and users in one place.On a server

Choosing

Questions to ask of any SCADA software.

Where does the data live?

On a server you control, or in someone else's cloud? Scadex runs on your own server, and the values, the history and the configuration stay on your hardware.

Does it work offline?

A plant should not stop for a network outage. Scadex has no licence server and no cloud account, and runs the same with every external cable unplugged.

What has each driver been tried with?

Ask for it plainly. Each of our connection pages says what its driver has run against, and where it has not been tried.

See the connections

Can you extend it?

Look for a documented API and a way to add drivers. Scadex has an open API, React hooks for your own screens and a module contract.

Build on Scadex

Who can change what?

Look for roles and a record of every change. Scadex gives every user a role, and records who made each change and when.

How many parts are there?

Fewer parts are easier to keep running. Scadex is one container with modules you switch on and off.

See the architecture

Questions

Short answers.

What does SCADA stand for?

Supervisory control and data acquisition. It is software that collects data from equipment, shows it to operators, raises alarms and lets people send commands, from one place.

Is SCADA the same as an HMI?

No. An HMI is an operator screen, often for one machine. SCADA supervises many controllers at once, keeps the history and ties the screens, the alarms and the users together.

Is SCADA the same as a PLC?

No. A PLC runs the control program of a machine or a process, and keeps running it without SCADA. SCADA sits above the controllers: it reads their values and sends setpoints and commands.

Does SCADA need the internet?

Not by itself. SCADA software can run entirely inside the plant's network. Scadex is self-hosted and runs the same with every external cable unplugged.

Which protocols do SCADA systems use?

Common ones are OPC UA, Modbus and MQTT, and many more exist for particular industries. Scadex connects to OPC UA, Modbus TCP and MQTT, and takes in Telegraf agents.

Can I run SCADA software on my own server?

Yes. Self-hosted SCADA runs on a server you own, inside your network, and the values, the history and the configuration stay on your hardware. Scadex runs as one container.

Interested in learning more?

Tell us about your plant and what you run today, or what you want to build on it. We answer in plain language.